Understanding diesel heater fuel consumption and running costs is important when choosing a heating system for a workshop, warehouse, garage or commercial building.

The AIRREX AH-500i uses approximately 1.05 litres of diesel per hour on Low (11 kW) and 1.42 litres per hour on High (15 kW). The AIRREX AH-900i uses approximately 1.81 litres per hour on Low (19 kW) and 2.30 litres per hour on High (24 kW).

These figures represent continuous operation at the selected output. In normal use, the built-in thermostat automatically controls the heater, switching the burner on and off to maintain the required temperature. This means actual daily fuel consumption can be considerably lower.

AIRREX Diesel Heater Fuel Consumption

Model Output Fuel Consumption Tank Capacity
AIRREX AH-500i 11–15 kW 1.05–1.42 l/h 45 litres
AIRREX AH-900i 19–24 kW 1.81–2.30 l/h 70 litres

What Affects Diesel Heater Running Costs?

Actual fuel consumption depends on several factors, including:

AIRREX infrared heaters heat people, floors, walls and surrounding objects directly rather than relying on a fan to circulate hot air. This can provide efficient, comfortable heat at working level and help reduce heat loss through high ceilings.

How Much Electricity Does an AIRREX Heater Use?

AIRREX heaters have a very low electrical power requirement because they do not use a fan.

The AH-500i uses approximately 50 W while operating, while the AH-900i uses approximately 60 W. Both models require a short period of higher power during start-up.

Which AIRREX Heater Do I Need?

The AIRREX AH-500i is suitable for heating spaces up to approximately 1,500 m³, while the AIRREX AH-900i is designed for spaces up to approximately 2,500 m³.

The correct heater will depend on the size, insulation and use of your building. If you're unsure which AIRREX diesel heater is right for your space, contact us for advice.

Fuel consumption figures are approximate and will vary depending on operating conditions, building insulation, ambient temperature and thermostat settings. AIRREX heaters must be used in accordance with the manufacturer's installation and operating instructions.

Back To List

Send Us A Message

Cookies

This website uses cookies. Please let us know if you agree to the use of these cookies :
I Accept I Decline

Privacy Policy | 3rd Party Data Processors | Disable Cookies
Cookies